
Sineng Electric has taken part in the 2026 edition of RE+ in Las Vegas, showcasing its latest technological advancements in grid-forming technology, power conversion and power quality management.
As AI data centres continue to expand, rapid GPU load fluctuations, increasing power demand and stringent power quality requirements are presenting new challenges for grid stability and power supply reliability. Sineng introduced three integrated power supply configurations through a system-level model: Renewable Energy Power Supply, Gas Turbine + Energy Storage and Gas Turbine + AI Power Block, highlighting flexible architectures for diverse AI data centre applications.
A key highlight was the company’s AI Power Block, an energy storage solution incorporating its string PCS on both the grid and load sides, a BESS and an MV bypass switch. Featuring dual-sided grid-forming control, the solution supports coordinated operation with the utility grid and on-site generation, including gas turbines and gas engines.
Serving as a fast-response power and energy buffer between generation sources and dynamic computing loads, the AI Power Block smooths rapid GPU load fluctuations while mitigating the impact of disturbances originating from either side. Its grid-side PCS provides dynamic voltage and frequency support, while the load-side PCS maintains independently regulated AC voltage for critical computing loads, enhancing both grid stability and power supply resilience.
Sineng also presented its comprehensive grid-forming energy storage portfolio, featuring both string and central PCS solutions compatible with battery energy storage systems exceeding 6 MWh in capacity.
The 430 kW string PCS, integrated into 6.25/6.88 MW MV Turnkey Stations, features advanced liquid-cooling technology that reduces temperature rise by 5 K and auxiliary power consumption by 30%. Cluster-level energy management improves battery capacity utilization by 7%, while automated SOC calibration reduces battery replenishment costs.
In the solar PV sector, Sineng displayed its 4.8 MW MV Turnkey Station and 510 kW high-power string inverter, featuring high-efficiency power conversion, intelligent protection, and optimized grid-support capabilities.
Also on display was the company’s Active Power Filter (APF), designed to meet the stringent power quality requirements of AI data centres and other mission-critical facilities.
Featuring millisecond-level dynamic response, the APF provides simultaneous harmonic mitigation, reactive power compensation and three-phase load balancing. With THDi of 5% or less, the solution supports compliance with applicable IEEE 519 harmonic limits, improves power factor and enhances transformer capacity utilization. By minimizing harmonic-related losses and associated heat generation, the APF enhances electrical system efficiency and supports reliable operation of critical power infrastructure.